SPECIFICATIONS

Input Voltage

12 to 24 Vdc +/- 10%

Maximum Input Current

1.5 A (340 mA excluding readers and USB)

Intelligent Controller Communication

2-wire RS-485, 2400 to 115K BPS, asynchronous

Inputs

7 supervised/unsupervised, standard EOL: 1k/1kΩ 1%, 1/4 watt

Outputs

4 Relays, Form-C with dry contacts

Normally Open Contact Rating

5 A @ 30 Vdc resistive

Normally Closed Contact Rating

3 A @ 30 Vdc resistive

Reader Power

12 Vdc +/- 10% regulated, 500 mA maximum each reader

Data Input Power

TTL compatible or 2-wire RS-485

OSDP Mode

9,600 to 230,400 bps, asynchronous, half-duplex, max cable 2000 ft (609.6 m)

LED Output (Wiegand)

Open Collector, 12 Vdc open circuit maximum, 40 mA sink maximum

Beeper Output (Wiegand)

Open Collector, 12 Vdc open circuit maximum, 40 mA sink maximum

Operating Temperature

32 to 158 ⁰F (0 to 70 ⁰C)

Humidity

5 to 85% RHNC

Storage Temperature

-67 to +185 °F (-55 to +85 °C)

Dimension

6.46" x 5.51" x 1.02" (164 mm x 140 mm x 26 mm)

Weight

342g

Certifications

Certification: FCC Part 15 Subpart B, CE, BSMI, IC, AS/NZS, TCVN, KCC

Safety: UL-294, IEC 62368-1, CB Scheme

Hazardous Substances: RoHS (2011/65/EU & 2015/863), EU REACH (1907/2006), California

Proposition 65

HS Code

8537.10.9

ECCN

EAR99